Lunch Box
15kv Current Transformer
2024-10-29 06:45  Visit:293
Price:Unfilled
Send inquiry
  • The current transformers are in accordance with GB20840.2-2014 and IEC60044-1 standards
  • Rated insulation level:12/42/75kV
  • Rated secondary current:5A or 1A
  • Rated frequency:50Hz or 60Hz
  • Ambient temperature:-5℃~+40℃
  • Pollution class IV

 

Main technical parameters

 

Rated primary current (A)

Accuracy classes combination

Rated output (VA)

1s thermal current (kA)

Rated dynamic current (kA)

20-40;40

0.2/0.5

0.5S/0.5

0.5/0.5

0.2/0.5

0.2/10P10

0.5/10P10

10P10/10P10

10P15/10P15

10P20/10P20

0.2S/0.5/10P10

0.2S/0.5/10P20

10/10

10/10

10/10

10/10

10/15

10/15

10/15

10/10

10/10

10/15/15

15/15/20

6.3

15

30-50;50

7.5

18.75

40-75;75

15

37.5

50-100;100

18

45

75-150;150

25

55

100-200;200

50

110

150-300;300

60

130

200-400;400

300-600;600

400-800;800

500-1000;1000

80

160

1200-1500;1500

 

The Complex Variable Technique Parameters

 

Rated primarycurrent(A)

Accuracy classes combination

Rated secondary output (VA)

1s thermal current (kA)

Rated dynamic current (kA)

10-15-20

0.2/0.2

0.2/0.5

0.5/0.5

0.2/10P10

0.5/10P10

0.2S/0.5/10P10

0.2S/0.5/10P20/10P20

10/10

10/10

10/10

10/15

10/15

10/10/15

15/15/20/20

2.7

4.5

15-20-30

4.2

6.6

20-30-40

6

9

30-40-50

9

11.5

40-50-75

11.3

16.5

50-75-100

16.8

22

75-100-150

24

33

100-150-200

33.6

45

150-200-300

45

63

200-300-400

45

80

300-400-500

45

100

500-600-800

80

130

600-800-1000

80

130

Note f the parameters requested by the user exceedthe range in the table above.Can be determined through consultationwith our company.The rated output and its corresponding accuracy level only meet one of these criteria.

 

Overall Dimension Drawing

 

 

The LZZBW-10 outdoor single-phase epoxy resin casting current transformer is used primarily in electrical power systems for measurement and protection. It is designed to transform high primary currents to a lower, manageable level for meters, relays, and other instruments.

 

Key Features

 

  • High Accuracy: Ensures precise measurement of current, which is crucial for both protection and metering applications.
  • Safety: Provides electrical isolation between the high-voltage primary circuit and the low-voltage secondary circuit.
  • Compact Design: Suitable for installation in various environments, including those with limited space.
  • Robust Construction: Designed to withstand harsh environmental conditions and electrical stresses.
  • Wide Range of Applications: Used in power plants, substations, and industrial settings for monitoring and protection purposes.
 
Specifications

 

  • Rated Primary Current: Typically ranges from 5A to several thousand amperes.
  • Rated Secondary Current: Commonly 1A or 5A.
  • Rated Voltage: 10 kV (indicated by the "10" in the model name).
  • Accuracy Class: Varies depending on the specific application but often falls within classes like 0.2, 0.5, 1.0 for metering, and 5P, 10P for protection.
  • Frequency: Designed for use in systems with a frequency of 50 Hz or 60 Hz.
  • Insulation Level: High insulation levels to ensure safe operation within high-voltage systems.
  • Thermal Current Rating: Ability to handle short-term overcurrents without damage.

 

Applications

 

  • Metering: Provides accurate current measurement for billing and monitoring.
  • Protection: Used in protective relays to detect faults and initiate protective measures.
  • Control Systems: Integral in control circuits for automated systems.
  • Power Quality Monitoring: Helps in monitoring and maintaining power quality by providing accurate current measurements.

 

https://www.youcin.com/

Message

TO: youxing888

E-mail:

Content:

Contact information
Comment
0